Home Oxygen Therapy
MA05.017f

Policy

​This policy uses coverage criteria developed solely based on applicable Medicare statutes, regulations, NCDs, LCDs, CMS manuals and other applicable Medicare coverage documents.

MEDICALLY NECESSARY​​​​ 

Initial coverage of home oxygen therapy and oxygen equipment is considered medically necessary and, therefore, covered for Groups I and II when all of the following criteria are met:
  • The treating professional provider has ordered and evaluated the results of a qualifying blood gas study (ie., oximetry test or arterial blood gas test) performed at the time of need. 
  • The individual's blood gas study meets the criteria (i.e., Group I, Group II) stated below.
  • The qualifying blood gas study or pulse oximetry study was performed by a qualified provider.
  • The provision of oxygen and oxygen equipment in the home setting will improve the individual's condition. 
NOTE: Time of need is defined as during the individual's illness when the presumption is that the provision of oxygen will improve the individual's condition in the home setting. For an inpatient hospital patient anticipated to require oxygen upon going home, the time of need would be within 2 days of discharge. ​​

GROUP I CRITERIA
Criteria from one of the following categories (i.e., while awake at rest, during exercise, or during sleep) must be met.

Individual Tested on Room Air
at Rest
Individual Tested During Exercise
Individual Tested During Sleep
While awake at rest:
  • Arterial oxygen saturation or pulse oximetry study at or below 88%; or
  • Arterial partial pressure of oxygen (PO2) at or below 55 mm Hg.
During exercise (defined as either the functional performance of the individual or a formal exercise test):
  • PO2 results while on room air at or below 55 mm Hg or an arterial oxygen saturation or pulse oximetry study at or below 88%; and
  • Documented improvement of hypoxemia during exercise with oxygen; for an individual with
  • PO2 results at or above 56 mm Hg or an arterial oxygen saturation or pulse oximetry study at or above 89% while at rest and on room air.
​
During sleep: 
  • If arterial PO2 at or above 56 mm Hg or an arterial oxygen saturation or pulse oximetry study at or above 89% while awake, additional testing must show:
    • ​Arterial PO2 at or below 55 mm Hg, or an arterial oxygen saturation or pulse oximetry study at or below 88%, taken during sleep; or
    • Decrease in arterial PO2 of more than 10 mm Hg, or a decrease in arterial oxygen saturation or pulse oximetry study more than 5%, taken during sleep associated with symptoms or signs reasonably attributable to hypoxemia, such as but not limited to the following indications:
      • ​Nocturnal restlessness with impaired cognitive processes
      • Insomnia with impaired cognitive processes

GROUP II CRITERIA​
The following criteria must be met:
  • Arterial oxygen saturation or pulse oximetry study of 89%; or
  • Arterial PO2 of 56-59 mm Hg; and 
  • Any of the following indications:
    • ​Dependent edema suggesting congestive heart failure
    • Pulmonary hypertension or cor pulmonale, determined by measurement of pulmonary artery pressure, gated blood pool scan, echocardiogram, or “P” pulmonale on EKG (P wave greater than 3 mm in standard leads II, III, or aVF)
    • Erythrocythemia with a hematocrit greater than 56%.
GROUP III CRITERIA

Initial coverage of home oxygen therapy and oxygen equipment is considered medically necessary and, therefore, covered for Group III, when both of the following conditions are met: 

  • Absence of hypoxemia defined in Group I and Group II above, and
  • A medical condition with distinct physiologic, cognitive, and/or functional symptoms documented in high-quality, peer-reviewed literature to be improved by oxygen therapy, such as but not limited to cluster headaches.​ ​
OTHER CONDITIONS
Initial coverage of oxygen therapy and oxygen equipment for individuals with other conditions not described in this policy may be limited to the shorter of 90 days or the number of days included in the professional provider's prescription if deemed medically necessary. Oxygen coverage may be renewed if deemed medically necessary. ​

​
CONTINUED COVERAGE CRITERIA BY OXYGEN GROUP
Group I
There is no formal requirement for re-evaluation and retesting; however, treating professional providers should ensure that once qualified for home oxygen therapy, the oxygen therapy and oxygen equipment remain reasonable and necessary.

Group II and Group III
  • ​A re-evaluation of a repeat qualifying blood gas test by the treating professional provider between the 61st and 90th days after initiation of therapy; and
  • A new Standard Written Order (SWO) by the treating professional provider. ​
LITER FLOW GREATER THAN 4 LITERS PER MINUTE (LPM) 
If initial coverage criteria for Group I, II, or III have been met, a ​higher allowance for a stationary system for a flow rate of greater than 4 LPM is eligible. For Group I and II, coverage greater than 4 LPM requires a qualifying blood gas study performed while the individual is on 4 or more LPM. If a flow rate of greater than 4 LPM is billed and the coverage criterion for the higher allowance is not met, the standard fee allowance will apply.​

PORTABLE OXYGEN
Portable oxygen systems are considered medically necessary and, therefore, covered when the individual is mobile within the home and the qualifying blood gas study or pulse oximetry study was performed while at rest (awake) or during exercise. If the only qualifying blood gas study or pulse oximetry study was performed during sleep, portable oxygen is considered not medically necessary and, therefore, not covered.

In addition, the use of portable oxygen in individuals who are mobile in the home and would benefit from the use of a portable oxygen system in the home is considered medically necessary and, therefore, covered when it is either by itself, or, to use in addition to a stationary oxygen system.

​NOT MEDICALLY NECESSARY

If all of the coverage conditions specified above for Group I, Group II, or Group III criteria are not met, home oxygen therapy is considered not medically necessary and, therefore, not covered.​​

GROUP IV CRITERIA 
Home oxygen therapy is considered not medically necessary and, therefore, not covered in any of the following conditions:
  • Angina pectoris in the absence of hypoxemia. This condition is generally not the result of a low oxygen level in the blood, and there are other preferred treatments.
  • Breathlessness without cor pulmonale or evidence of hypoxemia.
  • Terminal illnesses unless they affect the ability to breathe.
  • Severe peripheral vascular disease resulting in clinically evident desaturation in one or more extremities but in the absence of systemic hypoxemia. There is no evidence that increased PO2 will improve the oxygenation of tissues with impaired circulation.​
EMERGENCY OR STAND-BY OXYGEN
Emergency or stand-by oxygen for individuals who are not currently meeting the requirements for oxygen is considered not medically necessary, and, therefore, not covered because they are precautionary and not therapeutic in nature.

OXYGEN ACCESSORIES AND SUPPLIES

The non​invasive open ventilation system (NIOV) (E1352) by Breath Technologies, Inc., provides positive pressure inspiratory support for individuals using oxygen. This product consists of control unit, flow regulator, connecting hose and nasal interface (pillows) (A9900). Per the manufacturer, the NIOV is an item that is effective only when used in conjunction with oxygen. An item that is effective only when used in conjunction with oxygen is therefore classified as an accessory to oxygen equipment.
 
All home oxygen therapy equipment from contracted providers is rented rather than purchased. Oxygen supplies and accessories (e.g., nasal cannula, tubing, face mask, oxygen-conserving devices) are included in the rental reimbursement and are, therefore, not eligible for separate reimbursement.

TESTING SPECIFICATIONS

​When both ABG and pulse oximetry studies have been performed on the same day under the same conditions (i.e., at rest/awake, during exercise, during sleep) the ABG result will be used to determine if the coverage criteria were met. If an ABG test at rest/awake is nonqualifying, but an exercise or sleep oximetry study on the same day is qualifying, the oximetry study will determine the coverage.​

​

OVERNIGHT OXIMETRY STUDIES​
Overnight oximetry refers to stand-alone pulse oximetry continuously recorded overnight. It does not include oximetry results done as part of other overnight testing for sleep apnea such as polysomnography (PSG) or home sleep testing.

For home overnight oximetry studies, the oximetry provided to the individual must be tamper proof, have the capability to download data, allow documentation of the duration of oxygen desaturation below a specified value, and be under the direction of a diagnostic testing facility. ​Individuals may self-administer home-based overnight oximetry tests under the direction of a Medicare-enrolled independent diagnostic testing facility (IDTF). A durable medical equipment (DME) supplier may deliver a pulse oximetry test unit and related technology to an individual's home when the following criteria are met:
  • The individual's treating professional has contacted the IDTF to order an overnight pulse oximetry test before the test is performed.
  • The test is performed under the direction and/or instruction of a Medicare-approved IDTF.  Because it is the individual who self-administers this test, the IDTF must provide clear written instructions to the individual on proper operation of the test equipment and must include access to the IDTF in order to address other concerns that may arise. The DME supplier may not create this written instruction, provide verbal instructions, answer questions from the individual, apply or demonstrate the application of the testing equipment to the individual, or otherwise participate in the conduct of the test.
  • The test unit is sealed and tamper-proof such that test results cannot be accessed by anyone other than the IDTF, which is responsible for transmitting a test report to the treating professional provider. The DME supplier may use related technology to download test results from the testing unit and transmit those results to the IDTF. In no case may the DME supplier access or manipulate the test results in any form.

The IDTF must send the test results to the treating professional provider. The IDTF may send the test results to the supplier if the supplier is currently providing or has an order to provide oxygen or other respiratory services to the individual or if the individual has signed a release permitting the supplier to receive the report.


Oximetry test results obtained through a similar process as described for home overnight oximetry while the individual is awake, either at rest or with exercise, may not be used when qualifying the individual for home oxygen therapy.


OBSTRUCTIVE SLEEP APNEA (OSA), POLYSOMNOGRAPHY (PSG), AND HOME SLEEP TESTS​

For individuals with obstructive sleep apnea (OSA), the OSA must be sufficiently treated such that the underlying severe lung disease is unmasked. This must be demonstrated before oxygen saturation results obtained during PSG are considered qualifying for oxygen therapy. A qualifying oxygen saturation study may only occur during a titration polysomnographic study (either split night or stand-alone) if all of the following criteria are met:
  • The titration is conducted over a minimum of two hours; and
  • During titration:
    • The Apnea-Hypopnea Index/Respiratory Disturbance Index (AHI/RDI) is reduced to less than or equal to an average of 10 events per hour; or
    • If the initial AHI/RDI was less than an average of 10 events per hour, the titrations demonstrates further action in the AHI/RDI; and
  • Nocturnal oximetry conducted for the purpose for oxygen reimbursement qualification may only be performed after optimal positive airway pressure (PAP) settings have been determined and the individual is using the PAP device at those settings; and
  • The nocturnal oximetry conducted during the PSG demonstrates an oxygen saturation less than or equal to 88%.
To be eligible for coverage for home oxygen therapy for concurrent use with PAP therapy, the individual must meet all other coverage requirements for oxygen therapy. Individuals that qualify for oxygen therapy based on testing conducted only during the course of a sleep test are eligible only for reimbursement of stationary equipment.

EXERCISE TESTING​
When oxygen is covered based on an oxygen study obtained during exercise, there must be documentation of three oxygen studies in the individual's medical record (i.e., testing at rest without oxygen, testing during exercise without oxygen, testing during exercise with oxygen applied [to demonstrate the improvement of the hypoxemia]). All three tests must be performed within the same testing session. Only the qualifying test value (i.e., testing during exercise without oxygen) is used for qualification. The other results do not have to be routinely submitted but must be available on request.

The qualifying blood gas study or pulse oximetry test may be performed while the individual is on oxygen as long as the reported blood gas or pulse oximetry study values meet the Group I or Group II criteria.

All oxygen qualification testing must be performed in-person by the professional provider or other medical professional qualified to conduct oximetry testing. With the exception of overnight oximetry, unsupervised or remotely supervised home testing does not qualify as a valid test.​

CHRONIC OBSTRUCTIVE PULMONARY DISEASE

COVERAGE WITH EVIDENCE DEVELOPMENT (CED)
Home oxygen therapy for individuals diagnosed with chronic obstructive pulmonary disease (COPD) who have an arterial PO2 ranging from 56 mm Hg to 65 mm Hg, or an oxygen saturation at or above 89%, is eligible for coverage consideration under Medicare's Coverage with Evidence Development (CED) when individuals are enrolled in a clinical study approved by the Centers for Medicare & Medicaid Services (CMS) and sponsored by the National Heart, Lung, and Blood Institute (NHLBI).

Claims for individuals enrolled in the above clinical trial should be submitted to Medicare.

FACE-TO-FACE REQUIREMENTS

As a condition for payment, a professional provider must have a face-to-face encounter with the individual for whom the item is ordered that meets all of the following requirements:

  • The treating professional provider must have an in-person encounter with the individual within the 6 months prior to the date of the written order prior to delivery.
  • This encounter must document that the individual was evaluated and/or treated for a condition that supports the need for the item(s) of durable medical equipment (DME) ordered.​

A new face-to-face encounter is required each time a new standard written order for one of the specified items is ordered. A new standard written order is required:

  • For all claims for purchases or initial rentals
  • When there is a change in the standard written order for the accessory, supply, drug, etc.
  • If periodic standard written order renewal required per medical policy
  • When an item is replaced
  • When there is a change in the supplier​

In this policy the specified items are:

Code​
​Narrative
E0424 
Stationary compressed gaseous oxygen system, rental; includes container, contents, regulator, flowmeter, humidifier, nebulizer, cannula or mask, and tubing
E0431​
Portable gaseous oxygen system, rental; includes portable container, regulator, flowmeter, humidifier, cannula or mask, and tubing 
E0433 
Portable liquid oxygen system, rental; home liquefier used to fill portable liquid oxygen containers, includes portable containers, regulator, flowmeter, humidifier, cannula or mask and tubing, with or without supply reservoir and contents gauge 
E0434 
Portable liquid oxygen system, rental; includes portable container, supply reservoir, humidifier, flowmeter, refill adaptor, contents gauge, cannula or mask, and tubing 
E0439​ 
Stationary liquid oxygen system, rental; includes container, contents, regulator, flowmeter, humidifier, nebulizer, cannula, or mask, & tubing
E1390​ 
Oxygen concentrator, single delivery port, capable of delivering 85 percent or greater oxygen concentration at the prescribed flow rate 
E1391​ 
Oxygen concentrator, dual delivery port, capable of delivering 85 percent or greater oxygen concentration at the prescribed flow rate, each
E1392​
​Portable oxygen concentrator, rental
K0738 
Portable gaseous oxygen system, rental; home compressor used to fill portable oxygen cylinders; includes portable containers, regulator, flowmeter, humidifier, cannula or mask, and tubing​

REQUIRED DOCUMENTATION

The Company may conduct reviews and audits of services to our members regardless of the participation status of the provider. Medical record documentation must be maintained on file to reflect the medical necessity of the care and services provided. These medical records may include but are not limited to: records from the professional provider’s office, hospital, nursing home, home health agencies, therapies, and test reports. This policy is consistent with Medicare's documentation requirements, including the following required documentation:

STANDARD WRITTEN ORDER REQUIREMENTS
Before submitting a claim to the Company, the supplier must have on file a timely, appropriate, and complete standard written order for each item billed that is signed and dated by the professional provider who is treating the member. Requesting a provider to sign a retrospective standard written order at the time of an audit or after an audit for submission as an original standard written order, reorder, or updated order will not satisfy the requirement to maintain a timely professional provider order on file.

PROOF OF DELIVERY REQUIREMENT
Medical record documentation must include a contemporaneously prepared delivery confirmation or member’s receipt of supplies and equipment. The medical record documentation must include a copy of delivery confirmation if delivered by a commercial carrier and a signed copy of delivery confirmation by member/caregiver if delivered by the DME supplier/provider. All documentation is to be prepared contemporaneous with delivery and be available to the Company upon request.

CONSUMABLE SUPPLIES
The DME supplier must monitor the quantity of accessories and supplies an individual is actually using. Contacting the individual regarding replenishment of supplies should not be done earlier than approximately 7 days prior to the delivery/shipping date. Dated documentation of this contact with the individual is required in the individual’s medical record. Delivery of the supplies should not be done earlier than approximately 5 days before the individual would exhaust their on-hand supply.

For specified DME items, documentation of a face-to-face encounter, between the treating professional provider and the individual meeting the above requirements, including an assessment of the individual’s clinical condition supporting the need for the prescribed DME item(s) must be provided to and kept on file by the DME supplier.

If required documentation is not available on file to support a claim at the time of an audit or record request, the DME supplier may be required to reimburse the Company for overpayments.

Guidelines

This policy is consistent with Medicare's coverage criteria. The Company's payment methodology may differ from Medicare.

BENEFIT APPLICATION

Subject to the terms and conditions of the applicable Evidence of Coverage, home oxygen is covered under the medical benefits of the Company’s Medicare Advantage products when the medical necessity criteria listed in this medical policy are met.

However, services that are identified in this policy as not medically necessary or not eligible for separate reimbursement, are not eligible for coverage or reimbursement by the Company.

Description

Home oxygen therapy is most commonly used to treat chronic medical conditions that cause significant hypoxemia, such as severe lung disease (e.g., chronic obstructive pulmonary disease [COPD], interstitial fibrosis, cystic fibrosis, pulmonary neoplasm), pulmonary hypertension, and congestive heart failure related to cor pulmonale. Appropriate evidence of significant hypoxemia includes arterial blood gas studies, pulse oximetry, and certain clinical signs such as elevated pulmonary artery pressure, dependent edema, and polycythemia vera. 

Home oxygen has been used for cluster headache, which is a rare condition characterized by brief attacks of sudden, severe unilateral and periorbital pain. Cluster headache sufferers can have multiple attacks in a day, with each attack lasting anywhere from 15 minutes to 3 hours. Attacks are typically clustered over a period of 4 to 6 weeks. The intensity of pain is usually incapacitating throughout the duration of the attack. Studies have shown that the use of normobaric oxygen (oxygen at room pressure) delivered via a portable tank and face mask at a flow rate of 6 to 10 L/min for 5 to 15 minutes during an attack is effective in stopping the attack (abortive therapy).​

Home oxygen therapy may be delivered via nasal cannula, face mask, or transtracheal catheter. Supply sources include a stationary or portable compressed gas tank, stationary or portable liquid oxygen tank, or stationary oxygen concentrator. Any item that is effective only when used in conjunction with oxygen is therefore classified as an accessory to oxygen equipment.

References

Centers for Medicare & Medicaid Services (CMS). Coverage with evidence development. Home oxygen for COPD. [CMS Web site]. 12/01/2021. Available at: https://www.cms.gov/Medicare/Coverage/Coverage-with-Evidence-Development/Home-Oxygen-for-COPD. Accessed August 14, 2026.

Centers for Medicare & Medicaid Services (CMS). Decision Memo. Home Use of Oxygen (CAG-00296R3). [CMS Web site]. 07/08/2022. Available at: https://www.cms.gov/medicare-coverage-database/view/ncacal-decision-memo.aspx?proposed=Y&NCAId=307. Accessed August 14, 2026.


Centers for Medicare & Medicaid Services (CMS). National Coverage Determination (NCD).240.2: Home use of oxygen. [CMS Web site]. 01/23/2023. Available at: https://www.cms.gov/medicare-coverage-database/view/ncd.aspx?NCDId=169. Accessed August 14, 2026.​


Centers for Medicare & Medicaid Services (CMS). ​Decision Memo. NCA-Home Use of Oxygen and Home Oxygen to Treat Cluster Headaches (CAG-00296R2). [CMS Web site]. 09/27/2021. Available at https://www.cms.gov/medicare-coverage-database/view/ncacal-decision-memo.aspx?proposed=N&ncaid=301&areaId=s66&docType=NCA,CAL,NCD,MEDCAC,TA,MCD,6,3,5,1,F,P&contractOption=all&sortBy=relevance&bc=1. Accessed August 14, 2026.


Centers for Medicare & Medicaid Services (CMS). Federal Register. Medicare Program; Updates to Face-to-Face Encounter and Written Order Prior to Delivery List. Final Rule. [Federal Register Web site]. 01/17/2023. Available at: https://www.federalregister.gov/documents/2023/01/17/2023-00718/medicare-program-updates-to-face-to-face-encounter-and-written-order-prior-to-delivery-list. Accessed August 14, 2026.


Centers for Medicare & Medicaid Services (CMS). National Coverage Determination (NCD). 240.2.1: National Coverage Determination (NCD) for Home Use of Oxygen in Approved Clinical Trials. [CMS Web site]. 03/20/2006. Available at: https://www.cms.gov/medicare-coverage-database/view/ncd.aspx?NCDId=312. Accessed August 14, 2026.


Noridian Healthcare Solutions, LLC. Local Coverage Policy Article (LCA) A52514. Oxygen and oxygen equipment. [Noridian Healthcare Solutions Web site]. 04/01/2023. Available at: https://www.cms.gov/medicare-coverage-database/view/article.aspx?articleid=52514. Accessed August 14, 2026. 


Noridian Healthcare Solutions, LLC. Local Coverage Determination (LCD). L33797: Oxygen and oxygen equipment. [Noridian Healthcare Solutions Web site]. 04/01/2023. Available at: https://www.cms.gov/medicare-coverage-database/view/lcd.aspx?lcdid=33797&areaId=s6&docType=NCA,CAL,NCD,MEDCAC,TA,MCD,6,3,5,1,F,P&contractOption=all&sortBy=relevance&bc=1​. Accessed August 14, 2026. 

Noridian Healthcare Solutions, LLC. Breathe NIOV™ - Coding Reminder. [Noridian Healthcare Solutions Web site]. 08/23/2018. Available at: https://med.noridianmedicare.com/web/jadme/search-result/-/view/2230703/breathe-niov-coding-reminder. Accessed August 14, 2026.


Coding

CPT Procedure Code Number(s)
N/A

ICD - 10 Procedure Code Number(s)
Report the most appropriate diagnosis code in support of medically necessary criteria as listed in the policy.

ICD - 10 Diagnosis Code Number(s)
N/A

HCPCS Level II Code Number(s)
THE FOLLOWING CODES ARE USED TO REPRESENT OXYGEN EQUIPMENT:

E0424 Stationary compressed gaseous oxygen system, rental; includes container, contents, regulator, flowmeter, humidifier, nebulizer, cannula or mask, and tubing

E0425 Stationary compressed gas system, purchase; includes regulator, flowmeter, humidifier, nebulizer, cannula or mask, and tubing

E0430 Portable gaseous oxygen system, purchase; includes regulator, flowmeter, humidifier, cannula or mask, and tubing

E0431 Portable gaseous oxygen system, rental; includes portable container, regulator, flowmeter, humidifier, cannula or mask, and tubing

E0433 Portable liquid oxygen system, rental; home liquefier used to fill portable liquid oxygen containers, includes portable containers, regulator, flowmeter, humidifier, cannula or mask and tubing, with or without supply reservoir and contents gauge

E0434 Portable liquid oxygen system, rental; includes portable container, supply reservoir, humidifier, flowmeter, refill adaptor, contents gauge, cannula or mask, and tubing

E0435 Portable liquid oxygen system, purchase; includes portable container, supply reservoir, flowmeter, humidifier, contents gauge, cannula or mask, tubing and refill adaptor

E0439 Stationary liquid oxygen system, rental; includes container, contents, regulator, flowmeter, humidifier, nebulizer, cannula or mask, & tubing

E0440 Stationary liquid oxygen system, purchase; includes use of reservoir, contents indicator, regulator, flowmeter, humidifier, nebulizer, cannula or mask, and tubing

E0441 Stationary oxygen contents, gaseous, 1 month's supply = 1 unit

E0442 Stationary oxygen contents, liquid, 1 month's supply = 1 unit

E0443 Portable oxygen contents, gaseous, 1 month's supply = 1 unit

E0444 Portable oxygen contents, liquid, 1 month's supply = 1 unit

E0447 Portable oxygen contents, liquid, 1 month's supply = 1 unit, prescribed amount at rest or nighttime exceeds 4 liters per minute (LPM)

E1390 Oxygen concentrator, single delivery port, capable of delivering 85 percent or greater oxygen concentration at the prescribed flow rate

E1391 Oxygen concentrator, dual delivery port, capable of delivering 85 percent or greater oxygen concentration at the prescribed flow rate, each

E1392 Portable oxygen concentrator, rental

E1405 Oxygen and water vapor enriching system with heated delivery

E1406 Oxygen and water vapor enriching system without heated delivery

K0738 Portable gaseous oxygen system, rental; home compressor used to fill portable oxygen cylinders; includes portable containers, regulator, flowmeter, humidifier, cannula or mask, and tubing

S8120 Oxygen contents, gaseous, 1 unit equals 1 cubic foot

S8121 Oxygen contents, liquid, 1 unit equals 1 pound

THE FOLLOWING CODES ARE USED TO REPRESENT OXYGEN ACCESSORIES AND SUPPLIES AND ARE, THEREFORE, NOT ELIGIBLE FOR SEPARATE REIMBURSEMENT:

A4608 Transtracheal oxygen catheter, each

A4615 Cannula, nasal

A4616 Tubing (oxygen), per foot

A4617 Mouthpiece

A4619 Face tent

A4620 Variable concentration mask

A7525 Tracheostomy mask, each

E0455 Oxygen tent, excluding croup or pediatric tents

E0555 Humidifier, durable, glass or autoclavable plastic bottle type, for use with regulator or flowmeter

E0580 Nebulizer, durable, glass or autoclavable plastic, bottle type, for use with regulator or flowmeter

E1352 Oxygen accessory, flow regulator capable of positive inspiratory pressure

E1353 Regulator

E1354 Oxygen accessory, wheeled cart for portable cylinder or portable concentrator, any type, replacement only, each

E1355 Stand/rack

E1356 Oxygen accessory, battery pack/cartridge for portable concentrator, any type, replacement only, each

E1357 Oxygen accessory, battery charger for portable concentrator, any type, replacement only, each

E1358 Oxygen accessory, DC power adapter for portable concentrator, any type, replacement only, each

THE FOLLOWING CODE IS USED TO REPRESENT REPLACEMENT PILLOWS AND HOSES FOR THE NON-INVASIVE OPEN VENTILATION SYSTEM (NIOV) (E1352) AND IS NOT ELIGIBLE FOR SEPARATE REIMBURSEMENT:

A9900 Miscellaneous DME supply, accessory, and/or service component of another HCPCS code


Revenue Code Number(s)
N/A

Modifiers

QE Prescribed amount of stationary oxygen while at rest is less than 1 liter per minute (LPM)

QF Prescribed amount of stationary oxygen while at rest exceeds 4 liters per minute (LPM) and portable oxygen is prescribed

QG Prescribed amount of stationary oxygen while at rest is greater than 4 liters per minute (LPM)

QA Prescribed amounts of stationary oxygen for daytime use while at rest and nighttime use differ and the average of the two amounts is less than 1 liter per minute (LPM)

QB Prescribed amounts of stationary oxygen for daytime use while at rest and nighttime use differ and the average of the two amounts exceeds 4 liters per minute (LPM) and portable oxygen is prescribed

QR Prescribed amounts of stationary oxygen for daytime use while at rest and nighttime use differ and the average of the two amounts is greater than 4 liters per minute (LPM)​

Coding and Billing Requirements


Policy History

Revisions From​ MA05.017f:​
02/01/2027​This version of the policy will become effective 10/28/2026.

In accordance with Medicare Final Rule:

Face-to-Face Encounter and Written Order Prior to Delivery and/or Prior Authorization Requirement language has been added for HCPCS code K0738​

02/01/2027​This version of the policy will become effective 04/13/2026.

​In accordance with Medicare Final Rule:

Face-to-Face Encounter and Written Order Prior to Delivery and/or Prior Authorization Requirement language has been added for HCPCS codes ​E0424, E0431, E0433, E0434, E0439, E1390, E1391, E1392 .​


Revisions From​ MA05.017e:​​
​04/02/2025
​This policy was reviewed and reissued in accordance with the Company's Policy Annual Review Process. The adoptable source for this policy is Noridian.​
​07/10/2024

​This policy was reviewed and reissued in accordance with the Company's Policy Annual Review Process. The references were updated accordingly. The policy was updated to be consistent with current template wording and format. The adoptable source for this policy is Noridian.
​01/01/2024

​Effective 01/01/2024 this policy applies to New Jersey Medicare Advantage (MA) lines of business.​
07/17/2023​This version of the policy will become effective 07/17/2023.

​Policy criteria was revised in accordance with the Centers for Medicare & Medicaid Services National Coverage Determination 240.2 Home Use of Oxygen (effective 09/27/2021, implemented 01/03/2023) and Noridian Local Coverage Determination L33797 Oxygen and Oxygen Equipment and Noridian Local Coverage Article A52514 (effective 04/01/2023). ​

​Revisions From​ MA05.017d:
​10/24/2022
​This version of the policy will become effective 10/24/2022.

Language specific to Medicare's Coverage with Evidence Development (CED) for Custer H​​eadaches has been removed from this policy. This policy's formatting and organization has been updated for clarity.​

​Revisions From​ ​MA05.017c:
08/25/2021

​The policy has been reviewed and reissued to communicate the Co​mpany’s continuing position on Home Oxygen Therapy.​
08/17/2020This version of the policy will become effective 08/17/2020

In accordance with the Centers for Medicare & Medicaid Services' (CMS) Final Rule 1713 (84 Fed. Reg Vol 217), a face-to-face encounter has been removed for specified HCPCS codes:

E0441 Stationary oxygen contents, gaseous, 1 month’s supply = 1 unit

E0442 Stationary oxygen contents, liquid, 1 month’s supply = 1 unit

E0443 Portable oxygen contents, gaseous, 1 month’s supply = 1 unit

E0444 Portable oxygen contents, liquid, 1 month’s supply = 1 unit

E0447 Portable oxygen contents, liquid, 1 month's supply = 1 unit, prescribed amount at rest or nighttime exceeds 4 liters per minute (lpm)


In accordance with the Centers for Medicare & Medicaid Services' (CMS) Final Rule 1713 (84 Fed. Reg Vol 217), a face-to-face encounter has been added for specified HCPCS codes:

E1390 Oxygen concentrator, single delivery port, capable of delivering 85 percent or greater oxygen concentration at the prescribed flow rate

E1391 Oxygen concentrator, dual delivery port, capable of delivering 85 percent or greater oxygen concentration at the prescribed flow rate, each

E1392 Portable oxygen concentrator, rental

E1405 Oxygen and water vapor enriching system with heated delivery

E1406 Oxygen and water vapor enriching system without heated delivery

K0738 Portable gaseous oxygen system, rental; home compressor used to fill portable oxygen cylinders; includes portable containers, regulator, flowmeter, humidifier, cannula or mask, and tubing

The following HCPCS codes have been added to this policy:
S8120, S8121


Revisions From​ MA05.017b:
07/03/2019The policy has been reviewed and reissued to communicate the Company’s continuing position on Home Oxygen Therapy.
01/01/2019This policy has been identified for the HCPCS code update effective 01/01/2019.

The following HCPCS code has been added to this policy:

E0447 Portable oxygen contents, liquid, 1 month's supply = 1 unit, prescribed amount at rest or nighttime exceeds 4 liters per minute (lpm)

Revisions From MA05.017a:
05/09/2018The policy has been reviewed and reissued to communicate the Company’s continuing position on Home Oxygen Therapy.
04/25/2018The policy has been reviewed and reissued to communicate the Company’s continuing position on Home Oxygen Therapy.
06/21/2017This policy has been reissued in accordance with the Company's annual review process.
07/01/2016This version of the policy will become effective 07/01/2016.
  • Policy requirements regarding oxygen accessories and supplies have been added to this policy.
  • Policy requirements regarding oxygen therapy equipment have been revised in this policy.